LIEBERT-GP-NOTIFICATIONS-MIB DEFINITIONS ::= BEGIN IMPORTS sysUpTime FROM RFC1213-MIB MODULE-IDENTITY, OBJECT-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI lgpNotifications, liebertNotificationsModuleReg FROM LIEBERT-GP-REGISTRATION-MIB lgpConditionId, lgpConditionDescr, lgpConditionTime FROM LIEBERT-GP-CONDITIONS-MIB ; -- ============================================================================= -- Module Identification and Registration -- ============================================================================= liebertGlobalProductsNotificationsModule MODULE-IDENTITY LAST-UPDATED "200710290000Z" ORGANIZATION "Liebert Corporation" CONTACT-INFO "Contact: Technical Support Postal: Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus OH, 43229 US Tel: +1 (800) 222-5877 E-mail: monitoring@emersonnetworkpower.com Web: www.liebert.com Author: Craig S. Ward" DESCRIPTION "The MIB module used to register Liebert SNMP OIDs. Copyright 2000-2004 Liebert Corporation. All rights reserved. Reproduction of this document is authorized on the condition that the forgoing copyright notice is included. This Specification is supplied 'AS IS' and Liebert Corporation makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification." REVISION "200608150000Z" DESCRIPTION "Added events for firmware update successful and for firmware corrupt." REVISION "200602220000Z" DESCRIPTION "Added support for Liebert DS Unit." ::= { liebertNotificationsModuleReg 1 } -- ============================================================================= -- lgpNotifications - Liebert Notifications Registrations -- ============================================================================= lgpEventNotifications OBJECT-IDENTITY STATUS current DESCRIPTION "Notifications for Liebert Global Products." ::= { lgpNotifications 0 } lgpEventConditionEntryAdded NOTIFICATION-TYPE OBJECTS { lgpConditionId, lgpConditionDescr, lgpConditionTime } STATUS current DESCRIPTION "This notification is sent each time a condition is inserted into the conditions table." ::= { lgpEventNotifications 1 } lgpEventConditionEntryRemoved NOTIFICATION-TYPE OBJECTS { lgpConditionId, lgpConditionDescr, lgpConditionTime } STATUS current DESCRIPTION "This notification is sent each time a condition is removed from the conditions table." ::= { lgpEventNotifications 2 } lgpEventLowBatteryWarning NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The battery's remaining charge is less than or equal to the agent's configured low threshold 'lgpPwrConfigLowBatteryWarningTime'." ::= { lgpEventNotifications 3 } lgpEventLoadTransferedToBypass NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device has transfered the load to the bypass source." ::= { lgpEventNotifications 4 } lgpEventInternalFault NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device has reported an internal fault." ::= { lgpEventNotifications 5 } lgpEventBatteryTestFailed NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device has reported a battery self-test failure." ::= { lgpEventNotifications 6 } lgpEventOutputOverload NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device has reported an output overload condition." ::= { lgpEventNotifications 7 } lgpEventEstablishedPowerRedundancy NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device has transitioned to the user defined redundant state." ::= { lgpEventNotifications 8 } lgpEventLostPowerRedundancy NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The device as transitioned to a non-redundant power state as defined by the user configured threshold." ::= { lgpEventNotifications 9 } lgpEventPowerModuleFailure NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device power module failure." ::= { lgpEventNotifications 10 } lgpEventBatteryModuleFailure NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device battery module failure." ::= { lgpEventNotifications 11 } lgpEventControlModuleFailure NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device control module failure." ::= { lgpEventNotifications 12 } lgpEventPowerModuleWarning NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device power module warning." ::= { lgpEventNotifications 13 } lgpEventBatteryModuleWarning NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device battery module warning." ::= { lgpEventNotifications 14 } lgpEventControlModuleWarning NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Device control module warning." ::= { lgpEventNotifications 15 } lgpEventAgentFirmwareUpdateSuccessful NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The firmware update to the agent card has completed successfully." ::= { lgpEventNotifications 16 } lgpEventAgentFirmwareCorrupt NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "The firmware update to the agent card has failed and the firmware is now corrupt." ::= { lgpEventNotifications 17 } END